Description
The F-tone Networks 100GBASE-LR4 10km QSFP28 optical transceiver (FTQ2-HG-LR4-10xx) is designed for use in 100-Gigabit Ethernet links up to 10km on Single Mode Fiber (SMF). It is compliant with the QSFP28 MSA, IEEE 802.3ba 100GBASE-LR4 and IEEE 802.3bm CAUI-4. Digital diagnostics functions are available via the I2C interface, as specified by the QSFP28 MSA. It converts 4 input channels of 25.78125Gb/s electrical data to 4 channels of LAN-WDM optical signals and then multiplexes them into a single channel for 103.125Gb/s optical transmission. Reversely on the receiver side, the module de-multiplexes a 103.125Gb/s optical input into 4 channels of LAN-WDM optical signals and then converts them to 4 output channels of electrical data. The central wavelengths of the 4 LAN-WDM channels are 1295.56nm, 1300.05nm, 1304.58nm and 1309.14nm as members of the LAN-WDM wavelength grid defined in IEEE 802.3ba.

Features
● Hot-pluggable QSFP28 form factor
● 4 channels full-duplex transceiver module
● Supports 103.125Gb/s aggregate bit rate
● 4 channels DFB-based LAN-WDM cooling transmitter
● 4 channels PIN ROSA
● Internal CDR circuits on both receiver and transmitter channels
● 3.5W maximum power dissipation
● Maximum link length of 10km on SMF
● Duplex LC receptacle
● Single 3.3V power supply
● RoHS-6 compliant (lead free)
● Case operating temperature
     Commercial: 0 ~ +70℃
     Industrial: -40 ~ +85℃

Applications
● 100GBASE-LR4 100G Ethernet

Absolute Maximum Ratings

ParameterSymbolMinMaxUnit
Supply VoltageVcc-0.33.6V
Input VoltageVin-0.3Vcc+0.3V
Storage TemperatureTs-2085ºC
Case Operating TemperatureTc070ºC
Humidity (non-condensing)Rh585%
Damage Threshold (each lane)THd5.5dBm

Recommended Operating Conditions

ParameterSymbolMinTypicalMaxUnit
Supply VoltageVcc3.133.33.47V
Operating Case TemperatureTc070ºC
Data Rate Per Lanefd25.78125Gb/s
HumidityRh585%
Power DissipationPm3.5W
Link Distance with G.652D0.00210km

Electrical Specifications

ParameterSymbolMinTypicalMaxUnit
Supply CurrentIcc1.06A
Transceiver Power-on Initialization Time12000ms
Transmitter (each Lane)
Single-ended Input Voltage Tolerance-0.34.0V
AC Common Mode Input Voltage Tolerance15mV
Differential Input Voltage50mVp-p
Differential Input Voltage SwingVin900mVp-p
Differential Input ImpedanceZin90100110Ohm
Receiver (each lane)
Single-ended Output Voltage-0.34.0V
AC Common Mode Output7.5mV
Differential Output Voltage SwingVout300850mVp-p
Differential Output ImpedanceZout90100110Ohm

 Note:1. Power-on Initialization Time is the time from when the power supply voltages reach and remain above the minimum recommended operating supply voltages to the time when the module is fully functional.

Optical Characteristics 

ParameterSymbolMinTypicalMaxUnit
Lane WavelengthL01294.531295.561296.59nm
L11299.021300.051301.09nm
L21303.541304.581305.63nm
L31308.091309.141310.19nm
Transmitter
Side Mode Suppression RatioSMSR30dB
Total Average Launch PowerPT10.5dBm
Average Launch Power (each Lane)PAVG-4.34.5dBm
Optical Modulation Amplitude1 (each lane)POMA-1.34.5dBm
Difference in Launch PowerPtx,diff5dB
Launch Power in OMA minus TDP-2.3dBm
Transmitter and Dispersion Penalty (TDP) (each lane)TDP2.2dB
Extinction RatioER4dB
Relative Intensity NoiseRIN-130dB/Hz
Optical Return Loss ToleranceTOL20dB
Transmitter ReflectanceRT-12dB
Average Launch Power of OFF transmitter (each lane)POFF-30dBm
Eye Mask Coordinates2: X1, X2, X3, Y1, Y2, Y3{0.25, 0.4, 0.45, 0.25, 0.28, 0.4}
Receiver
Damage Threshold3 (each lane)THd5.5dBm
Total Receive Power10.5dBm
Average Receive Power (each lane)-10.64.5dBm
Receive Power (OMA) (each lane)4.5dBm
Receiver Sensitivity (OMA) (each lane)SEN-8.6dBm
Stressed Receiver Sensitivity (OMA)(each Lane)-6.8dBm
Difference in Receive Power between any Two Lanes (OMA)Prx,diff5.5dB
LOS AssertLOSA-18dBm
LOS De-Assert – OMALOSD-15dBm
LOS HysteresisLOSH0.5dB
Receiver Electrical 3 dB upper Cutoff Frequency (each Lane)Fc31GHz
Conditions of Stress Receiver Sensitivity Test5
Vertical Eye Closure Penalty5VECP1.8dB
Stressed Eye J2 JitterJ20.3UI
Stressed Eye J4 JitterJ40.47UI

Note:

  • Even if the TDP <1dB, the OMA min must exceed the minimum value specified here.
  • See the figure below.
  • The receiver shall be able to tolerate, without damage, continuous exposure to a modulated optical input signal having this power level on one lane. The receiver does not have to operate correctly at this input power.
  • Measured with conformance test signal at receiver input for BER =1×10-12.
  • Vertical eye closure penalty and stressed eye jitter are test conditions for measuring stressed receiver sensitivity. They are not characteristics of the receiver.

Mechanical Dimensions

Ordering Information

Product DescriptionPart Number
QSFP28 LR4, 103.125Gb/s, 1310nm, 10km, SMF, LC,0 ~ +70℃FTQ2-HG-LR4-10
QSFP28 LR4, 103.125Gb/s, 1310nm, 10km, SMF, LC,-40 ~ +85℃FTQ2-HG-LR4-10I

北亿纤通 | F-tone Networks

企业邮箱: sales@f-tone.com
企业手机:19081343401
企业电话:028-85255257
企业传真:028-85977702

注:本产品有全国产化型号可选

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.thers. Further details are available from any F-tone Networks sales representative.y F-tone Networks sales representative.

光学性能测试

测试光纤收发模块的眼图情况、接收灵敏度、消光比、波长、发光、光接收、电流和电压,以确保信号质量、传输的稳定性和可靠性。

Traffic Testing

测试误码率和丢包率,使其符合相应标准,确保收发器的性能。

光学性能测试

测试光纤收发模块的眼图情况、接收灵敏度、消光比、波长、发光、光接收、电流和电压,以确保信号质量、传输的稳定性和可靠性。

端面测试

检查光纤收发模块的端面并保持清洁,以实现更稳定的数据传输、更好的性能和耐用性。

兼容品牌:

华为 | 华三 | 中兴 | 锐捷 | Cisco | Juniper | Arista | Brocade |HPE ProCurve | HPE Aruba | HPE BladeSystem | HPE H3C | H3C | Dell | Extreme | HW | Generic | F-tone | Intel | Netgear | IBM | NVIDIA/Mellanox (Ethernet) | Ciena | Fortinet | Avago | Avaya | Alcatel-Lucent | D-Link | F5 | Ubiquiti | Mikrotik |Broadcom…..