Product Description
F-tone Networks’s FTCS-Bxx3G-xxxx series of transceiver modulesare the perfect solution for high -speed communication networks.These transceiver modules support data rates up to 3Gbps. The module is fully compliant with Small Form-Factor Pluggable (SFP) Transceiver Multi-Source Agreement (MSA).These transceiver modules provides the system designer with Camera, Video, HDTV/SDTV Fibre Channel applications.
Product Features
● DFB Laser Diode Transmitter
● Up to 40 Km on 9/125μm SMF
● 3.3V power supply
● LC duplex optical interface
● CML Differential Input/Output and LVTTL signal detect
● Support Video Pathological Patterns for SD-SDI,HD-SDI and 3G-SDI
● Class 1 Laser International Safety Standard IEC 825 Compliant
● Operating case temperature range (Standard:0 to+70℃)
Application
● SMPTE 259M/292M/424M Compliant Electrical-to-Optical Interfaces
● HDTV/SDTV Fibre Channel applications
Absolute Maximum Ratings
Operating of the transceiver beyond the Absolute Conditions Listed in Table 1 will degrade or damage the product. It’s not implied that the product would function above the recommended operating environment, it’s possible to reduce the reliability and lifetime of device if Recommended Operating Environment is exceeded (Refer to table 2)
Table 1— Absolute Maximum Conditions
| Parameter | Symbol | Min | Max | Units | Note |
| Storage Temperature | TST | -40 | +85 | ℃ | – |
| Relative Humidity | RH | 5 | 95 | % | – |
| Supply Voltage | VCC | 0 | +3.6 | V | – |
Table 2— Recommended Operating Environment and Electrical Characteristics
| Parameter | Symbol | Min | Typ | Max | Units | Note |
| Supply Voltage | VCC | +3.1 | +3.3 | +3.5 | V | – |
| Supply Current | Icc | – | – | 300 | mA | – |
| Operating Case Temperature | TOP | 0 | – | +70 | ℃ | – |
| Data Rate | B | 270 | – | 3000 | Mbps | – |
Optical Parameters
Table 3— FTCS-B133G-20xx Transceiver Optical Characteristics (Ambient Operating Temperature Ta=+25±5°C, VCC = 3.3±0.2V)
| Parameter | Symbol | Min | Typ | Max | Units | Note | |
| Transmitter | |||||||
| Data rate | B | 270 | – | 3000 | Mbps | – | |
| Output Center Wavelength | λc | 1260 | 1310 | 1360 | nm | – | |
| Output Spectral width (-20dB) | λ | – | – | 1 | nm | – | |
| Average Optical Output Power | Po | -5 | – | 0 | dBm | 1,2 | |
| Extinction Ratio | ER | 5 | – | – | dB | 1,2 | |
| Optic Output Eye: Compliant ITU-T G.957 | 1,2 | ||||||
| Receiver | |||||||
| Receiver Sensitivity | Pmin | – | – | -18 | dBm | 1,2 | |
| Receiver Saturation | Pmax | -3 | – | – | dBm | 1,2 | |
| Operation Center Wavelength | λc | 1480 | – | 1580 | nm | – | |
| Loss of Signal | Assert | LOSA | -30 | – | – | dBm | 1,2 |
| Deassert | LOSD | – | – | -18 | dBm | 1,2 | |
| LOS Hysteresis | LOSHYS | 0.5 | – | – | dB | – | |
Note1 :The optical power is launched into 9/125μm SMF.
Note2 :With a PRBS 223-1 test pattern@ 3000Mbps ,The sensitivity of the Pathological Patterns≦-16.
Table 4— FTCS-B153G-20xx Transceiver Optical Characteristics(Ambient Operating Temperature Ta=+25±5°C, VCC = 3.3±0.2V)
| Parameter | Symbol | Min | Typ | Max | Units | Note | |
| Transmitter | |||||||
| Data rate | B | 270 | – | 3000 | Mbps | – | |
| Output Center Wavelength | λc | 1480 | 1550 | 1580 | nm | – | |
| Output Spectral width (-20dB) | λ | – | – | 1 | nm | – | |
| Average Optical Output Power | Po | -3 | – | +2 | dBm | 1,2 | |
| Extinction Ratio | ER | 5 | – | – | dB | 1,2 | |
| Optic Output Eye: Compliant ITU-T G.957 | 1,2 | ||||||
| Receiver | |||||||
| Receiver Sensitivity | Pmin | – | – | -18 | dBm | 1,2 | |
| Receiver Saturation | Pmax | -3 | – | – | dBm | 1,2 | |
| Operation Center Wavelength | λc | 1260 | – | 1360 | nm | – | |
| Loss of Signal | Assert | LOSA | -30 | – | – | dBm | 1,2 |
| Deassert | LOSD | – | – | -18 | dBm | 1,2 | |
| LOS Hysteresis | LOSHYS | 0.5 | – | – | dB | – | |
Note1 :The optical power is launched into 9/125μm SMF.
Note2 :With a PRBS 223-1 test pattern@ 3000Mbps ,The sensitivity of the Pathological Patterns≦-16.
Table 5— FTCS-B133G-35xx Transceiver Optical Characteristics(Ambient Operating Temperature Ta=+25±5°C, VCC = 3.3±0.2V)
| Parameter | Symbol | Min | Typ | Max | Units | Note | |
| Transmitter | |||||||
| Data rate | B | 270 | – | 3000 | Mbps | – | |
| Output Center Wavelength | λc | 1260 | 1310 | 1360 | nm | – | |
| Output Spectral width (-20dB) | λ | – | – | 1 | nm | – | |
| Average Optical Output Power | Po | -3 | – | +2 | dBm | 1,2 | |
| Extinction Ratio | ER | 5 | – | – | dB | 1,2 | |
| Optic Output Eye: Compliant ITU-T G.957 | 1,2 | ||||||
| Receiver | |||||||
| Receiver Sensitivity | Pmin | – | – | -18 | dBm | 1,2 | |
| Receiver Saturation | Pmax | -3 | – | – | dBm | 1,2 | |
| Operation Center Wavelength | λc | 1480 | – | 1580 | nm | – | |
| Loss of Signal | Assert | LOSA | -45 | – | – | dBm | 1,2 |
| Deassert | LOSD | – | – | -18 | dBm | 1,2 | |
| LOS Hysteresis | LOSHYS | 0.5 | – | – | dB | – | |
Note1 :The optical power is launched into 9/125μm SMF.
Note2 :With a PRBS 223-1 test pattern@ 3000Mbps ,The sensitivity of the Pathological Patterns≦-16.
Table 6— FTCS-B153G-40xx Transceiver Optical Characteristics(Ambient Operating Temperature Ta=+25±5°C, VCC = 3.3±0.2V)
| Parameter | Symbol | Min | Typ | Max | Units | Note | |
| Transmitter | |||||||
| Data rate | B | 270 | – | 3000 | Mbps | – | |
| Output Center Wavelength | λc | 1480 | 1550 | 1580 | nm | – | |
| Output Spectral width (-20dB) | λ | – | – | 1 | nm | – | |
| Average Optical Output Power | Po | -3 | – | +2 | dBm | 1,2 | |
| Extinction Ratio | ER | 5 | – | – | dB | 1,2 | |
| Optic Output Eye: Compliant ITU-T G.957 | 1,2 | ||||||
| Receiver | |||||||
| Receiver Sensitivity | Pmin | – | – | -18 | dBm | 1,2 | |
| Receiver Saturation | Pmax | -3 | – | – | dBm | 1,2 | |
| Operation Center Wavelength | λc | 1260 | – | 1360 | nm | – | |
| Loss of Signal | Assert | LOSA | -30 | – | – | dBm | 1,2 |
| Deassert | LOSD | – | – | -18 | dBm | 1,2 | |
| LOS Hysteresis | LOSHYS | 0.5 | – | – | dB | – | |
Note1 :The optical power is launched into 9/125μm SMF.
Note2 :With a PRBS 223-1 test pattern@ 3000Mbps ,The sensitivity of the Pathological Patterns≦-16.
Electrical Parameters
Table 7— Transceiver Electrical Characteristics(Ambient Operating Temperature Ta=+25±5°C, VCC = 3.3 ±0.2V)
| Parameter | Symbol | Min | Typ | Max | Units | Note | ||
| Supply Voltage | VCC | +3. 1 | +3.3 | +3.5 | V | – | ||
| Supply Current | ICC | – | – | 300 | mA | – | ||
| Transmitter | ||||||||
| Differential Input Voltage | Vin | 400 | – | 2000 | mVP-P | – | ||
| Input Differential Impedance | Zin | 90 | 100 | 110 | Ω | – | ||
| TX_DISABLE | Disable | VD | 2.0 | – | Vcc | V | – | |
| Enable | VEN | 0 | – | 0.8 | – | |||
| TX_ Fault | Fault | VF | 2.0 | VCC | V | – | ||
| Normal | VN | 0 | – | 0.8 | – | |||
| Receiver | ||||||||
| Differential Output Voltage | VOUT | 400 | – | 2000 | mVP-P | – | ||
| RX_LOS | Fault | VF | 2.0 | – | Vcc | V | – | |
| Normal | VN | 0 | – | 0.8 | – | |||
Module Outline Drawing(Units in mm)

Order Information
| 产品型号 | 基本参数 |
| FTCS-B133G-20 | SFP 光模块-BIDI-1310nm TX/1550nm RX-3G SDI-20KM-商业级 |
| FTCS-B153G-20 | SFP 光模块-BIDI-1550nm TX/1330nm RX-3G SDI-20KM-商业级 |
| FTCS-B133G-35 | SFP 光模块-BIDI-1310nm TX/1550nm RX-3G SDI-35KM-商业级 |
| FTCS-B153G-40 | SFP 光模块-BIDI-1550nm TX/1330nm RX-3G SDI-40KM-商业级 |
| FTCS-B133G-20I | SFP 光模块-BIDI-1310nm TX/1550nm RX-3G SDI-20KM-工业级 |
| FTCS-B153G-20I | SFP 光模块-BIDI-1550nm TX/1330nm RX-3G SDI-20KM-工业级 |
| FTCS-B133G-35I | SFP 光模块-BIDI-1310nm TX/1550nm RX-3G SDI-35KM-工业级 |
| FTCS-B153G-40I | SFP 光模块-BIDI-1550nm TX/1330nm RX-3G SDI-40KM-工业级 |
北亿纤通 | F-tone Networks
企业邮箱: sales@f-tone.com
企业手机:19081343401
企业电话:028-85255257
企业传真:028-85977702
注:本产品有全国产化型号可选
本产品仅展示部分参数,如有需要,请您联系我们。
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.er protective rights of F-tone Networks or others. rther details are available from any F-tone Networks sales representative.ative.m any F-tone Networks sales representative.s sales representative.

光学性能测试
测试光纤收发模块的眼图情况、接收灵敏度、消光比、波长、发光、光接收、电流和电压,以确保信号质量、传输的稳定性和可靠性。
Traffic Testing
测试误码率和丢包率,使其符合相应标准,确保收发器的性能。


光学性能测试
测试光纤收发模块的眼图情况、接收灵敏度、消光比、波长、发光、光接收、电流和电压,以确保信号质量、传输的稳定性和可靠性。
端面测试
检查光纤收发模块的端面并保持清洁,以实现更稳定的数据传输、更好的性能和耐用性。


兼容品牌:
华为 | 华三 | 中兴 | 锐捷 | Cisco | Juniper | Arista | Brocade |HPE ProCurve | HPE Aruba | HPE BladeSystem | HPE H3C | H3C | Dell | Extreme | HW | Generic | F-tone | Intel | Netgear | IBM | NVIDIA/Mellanox (Ethernet) | Ciena | Fortinet | Avago | Avaya | Alcatel-Lucent | D-Link | F5 | Ubiquiti | Mikrotik |Broadcom…..